PRODUCTS: Tests Abstracts

A series of tests carried out worlwide, has been supplemented by tests carried out in accordance with relevant British Standards and American
Standards and these have indicated the total suitability of the material for roofing and cladding.

These are only some of the tests in which Onduline has performed entirely satisfactorily. Full test details are available from our offices.
 
General Tests

Accelerated Weather and U/V. BS2011. Warrington Research Laboratory Test (UK)     BS2011. Showed minimal change and colour fast rating 7, on Onduline PF



Strength and Impact Loading

Warrington Research Laboratory Test (UK) BS1811 and the United States Testing Co.     ASTMD 1502-60. Tests showed adequate bearing strength


Water and Weather Proofing

Tests (UK) BS1811 and ASTM D1499 (USA) showed excellent weather-proofing    characteristics.



Heat Deformation

Warrington Research Laboratory Test (UK). Tropical investigations test showed no    visible effects. Yarsley Research Centre Test (UK). Middle East suitability tests up to    70°C proved complete suitability in severe humidity and under all foreseeable    conditions

Mechanical Strength

 Warrington Research Laboratory Tests BS4154. Showed resistance to 73lbs sheered    force on fixing bolt.

Thermal Resistance (Insulation)

ASTM C177-76 (USA) and BS874 (UK). Showed excellent thermal resistance. K value   0.46 to 0.51 British Thermal Units.
Thermal Transmittance

 Warrington Research Centre. According to BS 874 the 'U' value is 0.43 Btu/h at hot   and cold face temperatures of 82°F and 55°F respectively.


Wind Lift

Tests by Miami and Metropolitan Dade County, Florida USA test code D70817 and   Yarsley Research Centre (UK). Proved Onduline suitable in hurricane and earthquake   conditions. Tested up to 120mph (192kph).



Hail/Frost Resistance

ASTM E196 (USA) and DIN 52103 and 52104 (Germany). Meets snow and frost   resistance for all regions. No mechanical damage in frost



Toxicity Tests

Yarsley Research Centre (UK). Tests carried out on water collected after catchment   with Onduline sheets gives water suitable for drinking complying with World Health   Organisation and EEC regulations



Fire Resistance

Warrington Research Laboratory Tests (UK). Show resistance to fire of up to Extl.   S.AA classification BS476.3 for Onduline AA Sheets.

Onduline sheets must be fully supported on roof decking and painted with a   proprietary AA surface paint treatment applied in accordance with the manufacturers   instructions to achieve an External S.AA fire rating. Contact the Technical Department  for details.

 Inflammability tests carried out in Russia in accordance with "OTM" method have   resulted in Onduline gaining Certification of accreditation GOST no. p.ru. 9001.6.2.0008   for use on buildings complying with normal fire regulations