These are only some of the tests in which Onduline has performed entirely satisfactorily. Full test details are available from our offices.
| |
|
 |
General Tests
Accelerated Weather and U/V. BS2011. Warrington Research Laboratory Test (UK) BS2011. Showed minimal change and colour fast rating 7, on Onduline PF
|
|
 |
Strength and Impact Loading
Warrington Research Laboratory Test (UK) BS1811 and the United States Testing Co. ASTMD 1502-60. Tests showed adequate bearing strength
|
|
 |
Water and Weather Proofing
Tests (UK) BS1811 and ASTM D1499 (USA) showed excellent weather-proofing characteristics.
|
|
 |
Heat Deformation
Warrington Research Laboratory Test (UK). Tropical investigations test showed no visible effects. Yarsley Research Centre Test (UK). Middle East suitability tests up to 70°C proved complete suitability in severe humidity and under all foreseeable conditions
|
|
 |
Mechanical Strength
Warrington Research Laboratory Tests BS4154. Showed resistance to 73lbs sheered force on fixing bolt.
|
|
 |
Thermal Resistance (Insulation)
ASTM C177-76 (USA) and BS874 (UK). Showed excellent thermal resistance. K value 0.46 to 0.51 British Thermal Units.
|
|
 |
Thermal Transmittance
Warrington Research Centre. According to BS 874 the 'U' value is 0.43 Btu/h at hot and cold face temperatures of 82°F and 55°F respectively.
|
|
 |
Wind Lift
Tests by Miami and Metropolitan Dade County, Florida USA test code D70817 and Yarsley Research Centre (UK). Proved Onduline suitable in hurricane and earthquake conditions. Tested up to 120mph (192kph).
|
|
 |
Hail/Frost Resistance
ASTM E196 (USA) and DIN 52103 and 52104 (Germany). Meets snow and frost resistance for all regions. No mechanical damage in frost
|
|
 |
Toxicity Tests
Yarsley Research Centre (UK). Tests carried out on water collected after catchment with Onduline sheets gives water suitable for drinking complying with World Health Organisation and EEC regulations
|
|
 |
Fire Resistance
Warrington Research Laboratory Tests (UK). Show resistance to fire of up to Extl. S.AA classification BS476.3 for Onduline AA Sheets.
Onduline sheets must be fully supported on roof decking and painted with a proprietary AA surface paint treatment applied in accordance with the manufacturers instructions to achieve an External S.AA fire rating. Contact the Technical Department for details.
Inflammability tests carried out in Russia in accordance with "OTM" method have resulted in Onduline gaining Certification of accreditation GOST no. p.ru. 9001.6.2.0008 for use on buildings complying with normal fire regulations |
|